Home > Pump > Chemical Pumps
I Summary Urea Pump
Model JINB third-generation-type melted urea pump is single-stage single-suction overhung centrifugal pump. It is used in transporting car amide liquids and other corrosive liquids which have not suspend grains. Temperature of medium is from -20℃~180℃.ENINE Urea Pump is level axial suction, discharges radial from top, there is temperature-preserved nip cover on front which can allow steam preservation of 0.59MPa,170℃.Materials can be selected according to the corrosive of medium, the model, flow and lift can be adjusted.
II Operating Performance Table For Urea Pump
model | capacity Q | head H M |
Speed n r/min |
power N (kw) | Efficiency % |
NPSH (m) |
||
M3/h | L/s | Shaft power | Motor power | |||||
JINB50-32-250 | 7.5 | 2.08 | 82 | 2900 | 7.28 | 11 | 23 | 2.0 |
12.5 | 3.47 | 80 | 8.25 | 33 | 2.0 | |||
15.0 | 4.17 | 78.5 | 8.79 | 36.5 | 2.5 | |||
JINB65-40-250 | 15.0 | 4.17 | 81.2 | 2900 | 6.76 | 15 | 34 | 2.0 |
25.0 | 6.94 | 80 | 11.84 | 46 | 2.0 | |||
30 | 8.33 | 78.4 | 12.8 | 50 | 2.5 | |||
JINB80-50-250 | 30 | 8.33 | 84 | 2900 | 14.61 | 30 | 47 | 2.6 |
50 | 13.9 | 80 | 18.80 | 58 | 2.6 | |||
60 | 16.7 | 75 | 20.78 | 59 | 3.0 | |||
JINB100-65-315 | 60 | 16.7 | 132 | 2900 | 44.9 | 75 | 48 | 2.8 |
100 | 27.8 | 125 | 54.9 | 62 | 3.2 | |||
120 | 33.3 | 119 | 60.8 | 64 | 4.2 | |||
JINB125-100-250 | 200 | 48.5 | 80 | 2900 | 54.9 | 75 | 62 | 3.2 |